Combination IO Modules

8DI+8AI+8DO Rugged Ethernet I/O

Item No.: M160
The M160T/E Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 10Mhz high speed pulse counter, 8 isolated 12bits analog inputs, supports 0~5V, 0~10V, 4~20mA,0~20mA analog signal, 8 digital outputs.
Introduction Features Specifications Download Applications
M160 Ethernet I/O
M series remote I/O covers a full range of units, including digital I/O, analog I/O, PT100 and PT1000 RTD I/O, Thermocouple I/O, pulse inputs and pulse outputs. The series is continuously expanded with application-specific modules.
The M series remote I/O modules features RS-485 Modbus I/O, support Modbus TCP server and client, Modbus RTU master and slave. And the M series is an Ethernet I/O Module used for IoT applications with SNMP V1/V2, MQTT. The remote industrial data acquisition module can be integrated into SCADA and other industrial automation systems, and also can be connected with cloud platform for remote monitoring and remote control. 
M160 Ethernet I/O Module comes with 8 digital inputs, 8 digital outputs, 8 analog inputs.
8DI
Wet/Dry contact
High speed pulse
counting
8DO
SINK
High speed pulse
output
8AI
0-20mA/4-20mA
0-5V
0-10V 
 Interface
     Ethernet port
     RS-485 serial port

                                          


Item Parameter Description
Power Input voltage
  1. Models without AO: 9~36VDC
  2. Models with AO: 24~36VDC
Power consumption Typical standby power consumption: ≤ 2W
Power Output
  1. 1 channel
  2. Output voltage: 936V DC
  3. Output current: 1500mA@12V(MAX)
Protection Reverse wiring prevention;
ESD Air: 15KV; Surge: 4KV
Ethernet Specification 1 x RJ45, 10M/100Mbps
Protection ESD contact: 8KV, Surge: 4KV(10/1000us)
Protocol Modbus RTU, Modbus TCP, MQTT
Serial port QTY 1 x RS485
Baud Rate 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000
Data Bit 7, 8
Parity Bit None, Even, Odd
Stop Bit 0.5, 1, 1.5, 2
Protocol Modbus RTU(slave), Modbus RTU(master)
Protection ESD contact: 8KV  Surge: 4KV(8/20us)
Digital input QTY 16 channel(Max)
Type Support Wet contact(NPN, PNP) and Dry contact.
Default: Wet contact
Dry contact
  1. Close: Short circuit
  2. Open: Open circuits
Wet contact
  1. Close: 10~30VDC
  2. Open: 0~3VDC
Others Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz.
Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz.
Isolated protection 2KVrms
Sampling Rate 100Hz
Digital output QTY 16 channels(Max)
Type SINK
Capacity 500mA per contact
Overvoltage protection 50VDC
Pulse output The first DO supports pulse output, pulse output frequency: 10Hz~300KHz
Analog input (12bit) QTY 8 channels(Max)
Method Differential input
Type 4-20mA, 0-20mA, 0-5V, 0-10V
Resolution 12Bit
Accuracy
  1. ±0.1% FSR @ 25°C
  2. ±0.3% FSR @ -10 and 60°C
  3. ±0.5% FSR @ -40 and 75°C
Sampling Rate 20Hz
Input Impedance
  1. Voltage type: >1M ohms
  2. Current type: 162 ohms
Analog input (16bit) QTY
  1. 8 channels(Max)
Method Differential input
Type 4-20mA, 0-20mA, 0-5V, 0-10V
Resolution
  1. 16Bit
Accuracy
  1. ±0.5‰FSR @ 25°C
Input Impedance
  1. Voltage type: >1M ohms
  2. Current type: 162 ohms
Software Protocols IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT
Protocol conversion Support Modbus TCP and RTU protocol conversion
Support Modbus RTU to MQTT and Modbus TCP to MQTT
Indicator light Power, Link, RS485_RXD, RS485_TXD, IO status
User configuration PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10
Map data bool: 300
16bit: 300
Login Package Support custom login package
Heartbeat Package Support custom heartbeat package
Environment Working -2070°C, 595%RH
Storage -4085°C, 595%RH
Others Case Metal
Dimension 82mm×40mm×100mm
Protection grade IP30
Net Weight 450g
Installation DIN rail mounted, Wall-mounted
industrial data acquisition
Description
M160 Ethernet I/O
M series remote I/O covers a full range of units, including digital I/O, analog I/O, PT100 and PT1000 RTD I/O, Thermocouple I/O, pulse inputs and pulse outputs. The series is continuously expanded with application-specific modules.
The M series remote I/O modules features RS-485 Modbus I/O, support Modbus TCP server and client, Modbus RTU master and slave. And the M series is an Ethernet I/O Module used for IoT applications with SNMP V1/V2, MQTT. The remote industrial data acquisition module can be integrated into SCADA and other industrial automation systems, and also can be connected with cloud platform for remote monitoring and remote control. 
M160 Ethernet I/O Module comes with 8 digital inputs, 8 digital outputs, 8 analog inputs.
8DI
Wet/Dry contact
High speed pulse
counting
8DO
SINK
High speed pulse
output
8AI
0-20mA/4-20mA
0-5V
0-10V 
 Interface
     Ethernet port
     RS-485 serial port

                                          


introduction
Features
Specifications
Item Parameter Description
Power Input voltage
  1. Models without AO: 9~36VDC
  2. Models with AO: 24~36VDC
Power consumption Typical standby power consumption: ≤ 2W
Power Output
  1. 1 channel
  2. Output voltage: 936V DC
  3. Output current: 1500mA@12V(MAX)
Protection Reverse wiring prevention;
ESD Air: 15KV; Surge: 4KV
Ethernet Specification 1 x RJ45, 10M/100Mbps
Protection ESD contact: 8KV, Surge: 4KV(10/1000us)
Protocol Modbus RTU, Modbus TCP, MQTT
Serial port QTY 1 x RS485
Baud Rate 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000
Data Bit 7, 8
Parity Bit None, Even, Odd
Stop Bit 0.5, 1, 1.5, 2
Protocol Modbus RTU(slave), Modbus RTU(master)
Protection ESD contact: 8KV  Surge: 4KV(8/20us)
Digital input QTY 16 channel(Max)
Type Support Wet contact(NPN, PNP) and Dry contact.
Default: Wet contact
Dry contact
  1. Close: Short circuit
  2. Open: Open circuits
Wet contact
  1. Close: 10~30VDC
  2. Open: 0~3VDC
Others Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz.
Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz.
Isolated protection 2KVrms
Sampling Rate 100Hz
Digital output QTY 16 channels(Max)
Type SINK
Capacity 500mA per contact
Overvoltage protection 50VDC
Pulse output The first DO supports pulse output, pulse output frequency: 10Hz~300KHz
Analog input (12bit) QTY 8 channels(Max)
Method Differential input
Type 4-20mA, 0-20mA, 0-5V, 0-10V
Resolution 12Bit
Accuracy
  1. ±0.1% FSR @ 25°C
  2. ±0.3% FSR @ -10 and 60°C
  3. ±0.5% FSR @ -40 and 75°C
Sampling Rate 20Hz
Input Impedance
  1. Voltage type: >1M ohms
  2. Current type: 162 ohms
Analog input (16bit) QTY
  1. 8 channels(Max)
Method Differential input
Type 4-20mA, 0-20mA, 0-5V, 0-10V
Resolution
  1. 16Bit
Accuracy
  1. ±0.5‰FSR @ 25°C
Input Impedance
  1. Voltage type: >1M ohms
  2. Current type: 162 ohms
Software Protocols IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT
Protocol conversion Support Modbus TCP and RTU protocol conversion
Support Modbus RTU to MQTT and Modbus TCP to MQTT
Indicator light Power, Link, RS485_RXD, RS485_TXD, IO status
User configuration PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10
Map data bool: 300
16bit: 300
Login Package Support custom login package
Heartbeat Package Support custom heartbeat package
Environment Working -2070°C, 595%RH
Storage -4085°C, 595%RH
Others Case Metal
Dimension 82mm×40mm×100mm
Protection grade IP30
Net Weight 450g
Installation DIN rail mounted, Wall-mounted
Download
Applications
industrial data acquisition

Review